Archived WU search doesn't work

Environment

http://10.241.12.207:8010/#/stub/Main

Description

This bug existed in 5.x build and doesn't seem to be fixed in 6.x either. Please can we have this fixed before 6.x goes to prod.

Conclusion

None

Activity

Show:

Kalaiarasi Easwaran July 19, 2016 at 7:09 PM
Edited

Tested in ECL Watch-Boca Dataland 6.0.4-rc1 and able to reproduce the above issue. Archived workunits are not returning in the selected date range.

Richard Chapman July 12, 2016 at 7:37 AM

Sounds like an issue in new EclWatch then ?

Anantha Venkatachalam July 11, 2016 at 7:52 PM

Isn't legacy going away in 6.x?

Kanghua Wang July 11, 2016 at 6:46 PM
Edited

In new ECLWatch, when you specify "from date:" to 7/2/2016 and "end date:" to 7/2/2016, ECLWatch shows all of the archived WUs in system. In legacy, ECLWatch shows the archived WUs in 7/2/2016.

Richard Chapman July 11, 2016 at 3:06 PM

Can you take a look

Fixed
Pinned fields
Click on the next to a field label to start pinning.

Details

Components

Assignee

Reporter

Priority

Compatibility

Point

Fix versions

Pull Request URL

Affects versions

Created July 11, 2016 at 2:44 PM
Updated July 28, 2016 at 1:00 PM
Resolved July 28, 2016 at 1:00 PM